Quantcast
Channel: custom
Viewing all articles
Browse latest Browse all 18

Need A Flange? We Can Do That!

$
0
0

I recently had a customer call in that was trying to boost an exhaust on a hot operation that he had in his facility.   We discussed what kind of fumes he was trying to evacuate and it appeared at face value that a High Temp Air Amplifier would be the perfect solution for his application.

A Model 121021 1-1/4" High Temp Air Amplifier directs hot air to a rotational mold cavity for uniform wall thickness of the plastic part.

A Model 121021 1-1/4″ High Temp Air Amplifier directs hot air to a rotational mold cavity for uniform wall thickness of the plastic part.

Then the words that strike fear into some manufacturers came out.  The customer asks, do you have any way to put a 4 bolt flange onto the unit so I can mount it straight into my piping system?   My response, “All I need are the dimensions of the flange you need and we will see what is possible.”  After a few further questions and verification, we had a drawing  with dimensions of a Flanged High Temp Air Amplifier.  We sent the drawing to the customer for approval, and once approved, we began to manufacture the custom product and provided it to the customer.  This unit will allow the customer to easily boost the exhaust on his operation and will bolt straight into his piping so there are no worries on his end about exhaust gas escaping.  His 500°F air temperature of the gases are of no concern to this special as it carries with it the high temperature rating of 700°F.  The pictures below show the Special – Flanged High Temp Air Amplifier.

IMG_5290

The air inlet and side view of the Special High Temp Air Amplifier

IMG_5291

Here you can see the low pressure side (intake) of the Special High Temp Air Amplifier.

IMG_5294

The O.D. of the flanges was 6″ with 4 – 3/4″: bolt holes. The Bolt holes were not required to align with the opposing side.

If you think there is no way we can find a product that will fit your compressed air application, or adapt a product to fit then give us a call, you might just be surprised at what we can offer in a quick turn around.

Brian Farno
Application Engineer Manager
BrianFarno@EXAIR.com
@EXAIR_BF

 


Filed under: Air Amplifier, Customer Service Tagged: 100% custom, 121021, air amplification, Air Amplifier, air blower, air mover, bdfarno, bolt flange, compressed air amplifier, custom, exahsut, exair, exhaust, first, first ever, flange, high temp, HT, industrial air movers, no one else, one of a kind, one-off, quick turn around, special, vacuum blower, venturi, venturi air movers